Privacy & Security Notice

Hanford Facility Beryllium Fact Sheet


Building Number/Name:
Date prepared:
Responsible Contractor:
Contact:

2101-HV (Tool Crib)
May 31, 2002
CH2M HILL Hanford Group, Inc.
N. K. Butler, (509) 376-5795


PAST OPERATIONS
Beryllium brought in facility: YES
Form of beryllium: SOLID
Period of beryllium operations (dates): Start: Early 1980s End: Present
Location(s) in facility that contained beryllium materials: Tool Crib and Machine Shop

Description of beryllium activities: Beryllium tools (beryllium-copper alloy containing about 2% beryllium) are stored in the tool crib and given to employees for use in Tank Farms. These tools are then returned to the tool crib, and may have small amounts of dust containing beryllium on them. Based on contacts with tool manufacturers, the potential for significant airborne exposure to beryllium from these tools is very low. However, because air sampling was not performed prior to the FDH beryllium assessment project, nor were measures taken to reduce the potential for employee exposure, the potential exists for exposure to low levels of airborne beryllium dust. As such, the tool crib is being considered a potential source of past airborne beryllium exposure.

Building monitoring data summary: None identified.

Personnel monitoring data summary: Four breathing zone and two area samples related to personnel were collected in 1998 to evaluate worker exposures to beryllium in the vicinity of the tool cribs. All six samples were below the detection limits of 0.2 mg/m3.

Specify Engineering/Administrative controls used during operations: Tools are wet-wiped before and after use.

Maximum Estimated Past Be exposure: LOW


CURRENT OPERATIONS
Building still present: YES
Beryllium present: YES

Current building occupancy/activity: Although beryllium tools are still being used, measures have been implemented to reduce the potential for airborne exposure to beryllium. These include wiping down the beryllium tools to reduce dust. Based on these measures, and airborne beryllium monitoring, current airborne exposure levels to beryllium are below detection limits.

1999 Study Results: Ambient air samples were collected on 6/9/99 and again on 6/24/99 just outside the entrance to the Tool Crib. A personal air sample was also collected on 6/9/99 in the breathing zone of a technician while wipe sampling surfaces for beryllium. Results reported for these samples were below the Method Detection Limit (MDL) of 0.006 µg/m3 and 0.005 µg/m3 for the ambient air samples and 0.007 µg/m3 for the personal sample, respectively. Surface samples were collected from 59 sites throughout the building on 6/9/99. Results reported for these samples were below the MDL of 0.5 mg/100 cm2.

Maximum Estimated Current Be Exposure from Routine Activities: NONE

Basis for above information: Conversations with Tank Farms Health and Safety regarding current procedures to minimize airborne exposure from beryllium tools; FDH beryllium assessment report.

Comments, including any additional information needed (specify): This area is included as a suspect beryllium facility as it is known to contain beryllium-copper alloy tools.